WINDLINK® H07 ZZ-F & LS0H UL/CSA EPR/XLEVA 1000V 90°C

Link senden drucken Ihr Kontakt
WINDLINK® H07 ZZ-F & LS0H UL/CSA EPR/XLEVA 1000V 90°C

CENELEC HD 22-13; draft EN 50525.2
Appliance Wiring Material UL 758 standard certified
1000 V +90°C
Style 3851 for single cores & Style 4559 for multi-cores
UL/CSA 22.2
AWM class I, II, or I / II , Group A,B, or A/B

UL CSA
Normen
International  CENELEC HD22-13
Beschreibung

Application

This cable is specially designed for Wind Turbines

The quality of material used for insulation and sheathing and high quality copper conductors make the cables both flexible, durable, resistant to torsion and to high temperatures. Nexans offers more than a decade of experience in the wind energy market. Our expertise makes WINDLINK® cables highly recommended for wind turbines.

 

Main characteristics

  • Frequent torsion: Excellent torsion behavior
  • Industrial cables resistant to high temperatures
  • Heavy duty
  • Temperature on core: 90°C in normal use; 250°C in short circuit
  • Water resistance: AD2, AD6
  • Corrosive and polluting substances resistance: AF3
  • Outdoor use : temporary and permanent
  • Impact resistance: AG2
  • Oil resistant ASTM/IRM 902 and special oils used in Wind machines
  • UV resistant for external application
  • Ozone resistant
  • Fire performances (IEC/EN 60332-1, EN 50265-1 and 2-1 )

 

Design 

1. Conductor :
Annealed plain copper-  Optional tape
Flexible (fine wire class 5 of IEC/EN 60228)

2. Insulation :
Special cross-linked improved for EI8 and EI7 ref HD 22.1 (low and high T°C temperature range)
Special thermoset EPR for high temperature
Optional tape on insulation or assembling

3. Sheath:
High mechanical performance , oil resistant
Ozone resistant, ref HD 22.1, black colour
Special cross-linked EM8 synthetic halogen free rubber, tested for EM7 application (90°C), improved for low temperature behaviour (-40°C)
Special thermoset XLEVA, halogen free rubber improved for low temperature behaviour (-40°C)
 


 TOP
Eigenschaften
Konstruktionsmerkmale
Leitermaterial Plain annealed copper  
Elektrische Eigenschaften
Nennspannung Uo/U CENELEC 450/750V, 600/1000V - UL CSA 1000V  
Mechanische Eigenschaften
Torsion test max. +/- 4 turns for 10 meters max:150° per meter  
Mechanische Festigkeit gegen Schläge Gut  
Anwendungsmerkmale
Rauchdichte LSF EN 61034-2  
UV Beständigkeit Very good  
Flammwidrig NFC 32070 C2, IEC 60332-1-2  
Watertightness AD2 to AD6  
Ölbeständigkeit Good  
Temperaturbereich bei freier Bewegung -40 .. 50°C  
Temperaturbereich bei fester Verlegung -40 .. 50°C  
Betriebstemperatur -40 .. 90°C  
Min. Betriebstemperatur -40°C  
Max. Betriebstemperatur am Leiter 90°C  
Max. Kurzschlusstemperatur am Leiter 250°C  

 TOP
Correspondance Sections in mm² and AWG

 

Sections in mm² 25 50 35 70 95 120 150 185 240 300 400
AWG (UL)

4
 AWG

1
AWG
2 AWG 2/0 AWG 3/0 AWG  4/0 AWG 250 MCM 350 MCM 450 MCM 550 MCM 750 MCM

 

 


 TOP
Complementary technical for Windlink®

Usage characteristics:

Mechanical stress :

(on the whole cable, per mm² of a cross section of plain copper core)

  • In normal use : 15 N/mm²

 

Mechanical characteristics:

Bending Radius

Mobile use = 6 x External diameter.
Static use = 3 x External diameter , if the external diameter < 12mm, 4 x if the external diameter >12 mm.

 

Electrical characteristics:

Permissible current rating: 

  • Permanent temperature of operation on the core 90°C
  • Ambient temperature for an outdoor installation  30°C

 

Correction factors according for other ambient temperature : according to IEC 60364.5.523 table 52.D1 or DIN VDE 0298-4 Table 15

Ambient
temperature (°C)
10 15 20 25 30 35 40 45 50 55 60 65 70 75
factors  1.17 1.13 1.09 1.04 1 0.96 0.91 0.87 0.82 0.76 0.69 0.62 0.54 0.45

The Voltage drop has been determined with Cos φ= 0.8

 

 Short circuit : constant K=139 Amps for 1 second, acc.to IEC 60949 ( short circuit temperature +250°C and conductor temperature +90°C)

 

 


 TOP
H07 ZZ-F & LS0H UL/CSA 1000V

 

Other properties

Standard tests according to CENELEC HD 22-13 or/and UL 758 standard style 3851 (single core), style 4559 (multi-core cables)
UV resistant sheath black sheath is UV resistant for external application

 

 

Oil resistant sheath good in oils, greases, gear box oil, etc
  • ASTM/IRM 902
24h at 100°C
  • Gear box oil  as Tribol 1710/320 or equiv oil.
72h at 40°C
  • Hydraulic oil as Mobil DTE 13m or equiv oil.
72h at 40°C

 TOP
Verkaufs- und Lieferinformationen

Marking

WINDLINK® NEXANS 213 USE < HAR > H07ZZ-F LS0H
Nb cores X (or G) S
X = without G/Y
G = with G/Y
S = cross section (mm2)
+ "UL/CSA" marking
Week + year manufacturing
meter marking

 

Insulated Cores identification

• 1 core = Black (preferential)
• 2 cores = Brown + Blue
• 3 cores = Green/Yellow +Blue + Brown (G)
Brown + Black + Grey (X S>4mm²)
Blue + Brown + Black (X S 1.5 & 2.5 mm²)
• 4 cores = Green/Yellow + Brown + Black + Grey (G)
Blue + Brown + Black + Grey (X S 1.5 & 2.5 mm²)


Nexans © copyright 2001 - 2012   Impressum | Kontakt | Inhaltsverzeichnis