Windlink® CAN BUS PUR cable

Link senden drucken Ihr Kontakt
Windlink® CAN BUS PUR cable

2 x 2 x 0.22mm²

Cabloswiss
Normen
International  ISO 11898-2
Beschreibung

Application

The cables are used in windturbines. Among other things the CanBus cable connects the hub-box with a box in nacelle.
Notice that the cable is exposed too high temperature in the gearbox and main shaft and in contact with gear and hydraulic oil
 

Construction

Conductor Bare copper 7 x 0.203 mm (Section 0.22 mm2)
 
Insulation:

Insulation: TPE compound
Colour Code: 4 Cores White-Green-Brown-Yellow 
Diameter: 1.40 ± 0.1 mm 

Assembly:

Center: Fibrillated polypropilene filler
Layer:   4 Cores twisted together in quad (Sequence White-Green-Brown-Yellow) + polyester tape.
Can Bus pairs White+Brown , Green+Yellow 
  

Screen:

Aluminium/Polyester Tape (alu outside)
braided screen of tinned copper wires
(Coverage ≥ 85%) + non woven tape
 

Sheath:
Polyurethane compound, polyether based, halogenfree, flame retardant, oil resistant
Colour code: Black Ral 9005
Overall diameter: 6.4 ± 0.3 mm
 

 

Cable marking:

CABLOSWISS – Week/Year of production - WINDLINK CAN BUS PUR 2x2x0.22mm² Meter marking
Marking according to DIN47100

 


 TOP
Eigenschaften
Konstruktionsmerkmale
Leitermaterial Kupfer, blank  
Isolierung Protection kit  
Schirm Kupfergeflecht, verzinnt  
Außenmantel Polyurethane compound LSZH  
Halogenfrei Ja  
Elektrische Eigenschaften
Wellenwiderstand bei 1 MHz 120Ohm  
Anwendungsmerkmale
UV Beständigkeit IEC 60068-2-5  
Ölbeständigkeit IEC 60811-2-1  
Ozonbeständigkeit EN 60811-2-1  
Flammwidrig IEC 60332-1  
Rauchdichte EN 50268  
Korrosivität der (Brand-)Gase EN 50267  
Betriebstemperatur -25 .. 100°C  
RoHS konform ja  
Lagertemperatur, Bereich -45 .. 80°C  

 TOP
Technical characteristics on CAN BUS cable
UV resistant The cable has to be UV-resistant according to IEC 60068-2-5
Mechanical properties

Mechanical properties of insulation and sheathing compound:
The cable has to fulfil relevant tensile and elongation tests according to IEC60811-1-1, clause 9

Oil resistant

The cable has to be oil resistant. Test according to EN60811-2-1 (based on to IEC60811-2-1)
Standard test oil ASTM No. 2 24h at 100°C
Max tensile strength variation: +/- 40% (HD22.10, attachment A)
Max change of elongation at break: +/- 40% (HD22.10, attachment A)

Additional the cable has to be resistant to the used gear-and hydraulic oil.
Gear oil: Tribol 1710/320 150 days at 100°C
Hydraulic oil: Mobil DTE 13 M, Shell Tellus Arctic 32, Castrol AWH-M 32 140 days at 100°C  

Max tensile strength variation: - 50%
Max change of elongation at break: - 50%

Thermal endurance graph (Arrhenius) and life expectancy of sheath material acc. to ISO2578
Gear oil: 18 years at 65°C (more than 25 years at 20°C)
Hydraulic oil: 24 years at 65°C (more than 25 years at 20°C)

Ozone resistant The cable has to be ozone resistant. Test according to EN60811-2-1, clause 8 (or HD22.2 S3, clause 7.3)
Flame retardant The cable has to be flame retardant and self extinguish. Behavior on fire according to EN50265-2-1 (based on to IEC60332-1)
Low emission of smoke

The cable has to have low emission of smoke. Smoke visibility according to EN50268 (based on IEC61034)

Level for smoke visibility is >35%

Halogen free

Halogen free - Low emission of corrosive gases (acidic gases):
The cable has to be halogen free, have low emission of corrosive gases and acid.
Halogen free – without Chlorine, Fluorine and Bromine
Corrosive gases and acid content according to HD22.13 and EN50267-1 and EN50267-2 (based on IEC60754)
Gases from burned cables have a conductivity < 10µS/mm and pH > 4.3

Mechanical stress

Vibrations continuously affect the cables.
Bending radius:

  • Moving application 10 x diameter
  • Fixed application 5 x diameter

Permissible pulling force > 15 N/mm2

Temperature range
  • Operation: -25°C to +100°C.
  • Standstill: -45°C to +100°C.
Electrical data

Impedance at 1MHz: 120 Ohm +/-15%

Conductor resistance, max.: 98.0 Ohm/km @20°C

Capacitance at 800Hz, nominal: 41nF/km

Insulation resistance, min.: 1 GOhmxkm (20°C and 500V)

Test voltage (AC, 1 min) 1.2kV (core/core and core/screen)  

Life time The lifetime has to be 25 years based on the positive results on mechanical stress test

 TOP
More information

Cable sheath shall be provided with:

  • Manufacture name (trademark) and type
  • Production year/week or batch number
  • Meter marking

 

About Sheath surface:  

The surface of the cable sheath has to be uniform and homogeneous. This means:

  • That structure of the surface has to be uniform.
  • The surface must not be discolored.
  • There must be no swelling, no notch, no cut and no marks visible in the surface. •
  • The sheath must not show any signs of having been roughly treated.

 

 


 TOP
Nexans © copyright 2001 - 2012   Impressum | Kontakt | Inhaltsverzeichnis