IEC 60502-2 HYPRON® Unarmoured Fire retardant

Neu
Link senden drucken Ihr Kontakt
IEC 60502-2 HYPRON® Unarmoured Fire retardant - Power cables 3.6/6 (7.2) kV, 6/10 (12) kV, 8.7/15 (17.5) kV, 12/20 (24) kV, 18/30 (36) kV
- Lead free
- Aliphatic and aromatic hydrocarbons resistant.
Normen
International  IEC 60228; IEC 60332-3-22 Cat.A
Beschreibung

Applications

These power cables are used for electricity supply in medium voltage installation system where chemicals may be present. Hypron® offers an alternative fo conventional lead covered cable and is an environmental friendy solution .

 

Design

Conductor:

Stranded bare copper (class 2)

Semi-conductor

Insulation:

Cross-linked polyethylene (XLPE)

Semi-conductor

Screen:

Copper tape

Bedding (Optional):

An inner sheath acting as a filler with practically zero thickness

Inner sheath:

Polyvinyl chloride (PVC) Colour black

Screen/sealing barrier:

 Aluminium/polyethylene tape

Sheath:

High density polyethylene (PE) Colour: black

Special sheath (intermediate sheath):

Polyamide

Outer sheath:

Polyvinyl chloride (PVC). Colour: red. Other colour on request.

 

Core identification

1 core: natural
3 x: black – green – brown (by tape under copper screen)
 

 

Marking

NEXANS 279 XLPE/PVC/AL/HDPE/NC/PVC VOLTAGE Nber of cores and cross section Cu/Alu IEC 60332-3-22(A) MM YYYY manufacturing number + meter marking

 

Standards

IEC 60502-2 (design guide-lines)



Dokumente zum Thema
  Electrical_characteristics_IEC_60502_2_HYPRON_Unarmoured  (43.4kb)



 TOP
Eigenschaften
Konstruktionsmerkmale
Leitermaterial Kupfer, blank  
Leitertype Stranded, Class 2  
Isolierung VPE (vernetztes Polyethylen)  
Schirm Querleitwendel  
Innenmantel PVC  
Zwischenmantel Polyamide  
Außenmantel PVC  
Bleifrei Ja  
Schutz no  
Anwendungsmerkmale
flammwidrig IEC 60332-3-22  
Chemische Beständigkeit Aliphatic and aromatic hydrocarbons resistant  
Max. Betriebstemperatur am Leiter 90°C  
Betriebstemperatur -20 .. 60°C  
UV Beständigkeit Ja  

 TOP
Parametrische Suche
Aderanzahl  
Leiterquerschnitt  mm²
Nennspannung Uo/U  
Ausführen
Zurücksetzen
Ihre Wahl   82/82
Alle Artikel wählen Nexans Ref. Name Ader- zahl Leiter (mm²) Nenn- spannung Uo/U
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 25 1 25 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 25 1 25 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 25 1 25 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 25 1 25 18 / 30 (36) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 35 1 35 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 35 1 35 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 35 1 35 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 35 1 35 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 50 1 50 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 50 1 50 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 50 1 50 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 50 1 50 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 50 1 50 18 / 30 (36) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 70 1 70 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 70 1 70 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 70 1 70 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 70 1 70 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 70 1 70 18 / 30 (36) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 95 1 95 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 95 1 95 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 95 1 95 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 95 1 95 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 95 1 95 18 / 30 (36) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 120 1 120 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 120 1 120 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 120 1 120 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 120 1 120 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 120 1 120 18 / 30 (36) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 150 1 150 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 150 1 150 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 150 1 150 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 150 1 150 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 150 1 150 18 / 30 (36) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 185 1 185 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 185 1 185 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 185 1 185 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 185 1 185 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 185 1 185 18 / 30 (36) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 240 1 240 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 240 1 240 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 240 1 240 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 240 1 240 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 240 1 240 18 / 30 (36) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 300 1 300 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 300 1 300 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 300 1 300 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 300 1 300 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 400 1 400 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 400 1 400 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 400 1 400 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 400 1 400 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 500 1 500 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 500 1 500 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 500 1 500 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 500 1 500 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 630 1 630 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 630 1 630 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 630 1 630 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 1 x 630 1 630 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 25 3 25 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 25 3 25 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 25 3 25 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 35 3 35 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 35 3 35 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 35 3 35 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 35 3 35 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 50 3 50 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 50 3 50 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 50 3 50 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 50 3 50 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 70 3 70 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 70 3 70 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 70 3 70 8.7 / 15 (17.5) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 70 3 70 12 / 20 (24) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 95 3 95 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 95 3 95 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 120 3 120 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 120 3 120 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 150 3 150 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 150 3 150 6 / 10 (12) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 185 3 185 3.6 / 6 (7.2) kV
Make to order product   Neu IEC 60502-2 HYPRON® Unarmoured 3 x 185 3 185 6 / 10 (12) kV
Zu den Favoriten hinzufügen

 TOP
Verkaufs- und Lieferinformationen

Other fire performances IEC 60332-1 or IEC 60332-3-24(C) on request.


Minimum bending radius:

1 core: 10 x outer diameter
3x: 8 x outer diameter
To be doubled during laying operations


Aluminium conductors available on request


Zusatzinformation
IEC 60502-2 HYPRON® Unarmoured Fire retardant   Electrical_characteristics_IEC_60502_2_HYPRON_Unarmoured (43 kB)

Nexans © copyright 2001 - 2012   Impressum | Kontakt | Inhaltsverzeichnis