MPRXCX® FLEXISHIP® EMC
1.8/3 (3.6) kV
MPRXCX® FLEXISHIP EMC 1.8/3kV 3 x 70
Nexans ref. 25491789
- Packaging: Cut to length (m)
- Construction type: 3 x 70
- With Green/Yellow core: No
- Minimum outer diameter: 38.5 mm
- Maximum outer diameter: 42.5 mm
- Approximate weight: 3536 kg/km
- Permissible current rating in open air: 169 A
MPRXCX® FLEXISHIP EMC 1.8/3kV 3 x 95
Nexans ref. 25491790
- Packaging: Cut to length (m)
- Construction type: 3 x 95
- With Green/Yellow core: No
- Minimum outer diameter: 44.0 mm
- Maximum outer diameter: 48.5 mm
- Approximate weight: 4421 kg/km
- Permissible current rating in open air: 205 A
MPRXCX® FLEXISHIP EMC 1.8/3kV 3 x 120
Nexans ref. 25491791
- Packaging: Cut to length (m)
- Construction type: 3 x 120
- With Green/Yellow core: No
- Minimum outer diameter: 47.0 mm
- Maximum outer diameter: 52.0 mm
- Approximate weight: 5486 kg/km
- Permissible current rating in open air: 237 A
MPRXCX® FLEXISHIP EMC 1.8/3kV 3x120+3G25
Nexans ref. 25491797
- Packaging: Cut to length (m)
- Construction type: 3x120+3G25
- With Green/Yellow core: Yes
- Minimum outer diameter: 47.0 mm
- Maximum outer diameter: 52.0 mm
- Approximate weight: 5840 kg/km
- Permissible current rating in open air: 237 A
MPRXCX® FLEXISHIP EMC 1.8/3kV 3 x 150
Nexans ref. 25491792
- Packaging: Cut to length (m)
- Construction type: 3 x 150
- With Green/Yellow core: No
- Minimum outer diameter: 51.0 mm
- Maximum outer diameter: 56.5 mm
- Approximate weight: 6574 kg/km
- Permissible current rating in open air: 273 A
MPRXCX® FLEXISHIP EMC 1.8/3kV 3x150+3G25
Nexans ref. 25491798
- Packaging: Cut to length (m)
- Construction type: 3x150+3G25
- With Green/Yellow core: Yes
- Minimum outer diameter: 51.0 mm
- Maximum outer diameter: 56.5 mm
- Approximate weight: 6911 kg/km
- Permissible current rating in open air: 273 A
Description
Description
Standards
-
ProductIEC 60228
-
InstallationIEC 60092-350; IEC 60092-353; IEC 60092-360
-
TestIEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
Motor supply cable for frequency converters controlled low voltage AC drives on ships, called VFD applications. MPRXCX® FLEXISHIP® EMC cables are designed with a special coverage, copper-polyester tape and braid, which provide a 100% EMC protection. Insulation with low dielectric constant is used to reduce reflected wave voltage peak magnitude.
Symmetrical insulated ground wires, placed in corner, can reduce reflected wave and return common mode noisy currents back to the drive. Enhanced insulation is implemented for 1.8/3(3.6) kV cable to fulfil periodic peak voltage up to 3 kV due to harmonics.
These cables are used on board of ships in all locations for fixed installations.
Design
- Conductor
Flexible bare copper
Class 5
- Insulation
XLPE (cross-linked polyethylene)
- Optional
Symmetrical return earth conductors
- Inner covering
Lapped or extruded
- Screen / Armouring
Copper / polyester tape
Bare copper braid
- Outer sheath
Polyolefin SHF1 (SHF2 on request)
Colour: red
Marking
I NEXANS I MPRXCX FLEXISHIP EMC 1.8/3kV "n"x"s"mm2 90°C
IEC 60092-353 IEC 60332-3-22 Cat. A ww/yy + metric marking
Core Identification
3 cores: black-grey-brown
Earth: green/yellow split in 3 conductors
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania