604 - Screened and jacketed wires and cables

Description
604 - Screened and jacketed hook-up wires and multicore cables
Description
Standards
National : NF C 32-070/C1Description
MAIN CHARACTERISTICS
Flexible cables and lightweight serie with PVC + superpolyamide insulation for use in low temperature areas. Abrasion resistance: good.They are fire retardant (to NFC 32070/C1 French specification). They withstand most chemical fluids except for concentrated nitric acid.
STANDARDS
To AIR 4524 & MIL-W 5086B/7A specifications. These cables are approved by the Air Ministry under letters: N° 33587 STA/EQ/E2 (30-3-72) for AWG 24 N° 41762 STA/EQ/E2 (12-11-68) for AWG 22 up to AWG 8 Registered at B.N.Aé : N° 6412 411 A .
TECHNICAL REQUIREMENTS AND CONTROL CONDITIONS
Screen: to MIL.C. 7078C (August 1971) U.S. spécification. Colour coding: to Air 0107 A (october 1961) and note N° 348/SIB distributed under n° 5927/STT/SIB (3 mai 1961).
COLOUR CODING
To Air 0107 A (October 1961) and note N° 348/SIB distributed under n° 5927/STT/SIB (3 May 1961). .
CONSTRUCTION
BASE CORE 1604
- CONDUCTOR
stranded tinned copper wires or stranded tinned copper alloy wires for cross section 0.21mm²
- INSULATION
polyvinyl chloride (PVC ).
- OUTER JACKET
superpolyamide (radial thickness: from 0.10 mm up to 0,15 mm)
604
- LAY UP
1 or several 1604 cores
- SCREEN
tinned copper braid (Kr>= 62%)
- OUTER JACKET
superpolyamide (radial thickness: about 0.20mm)
Characteristics
Construction characteristics | |
---|---|
Conductor material | Tinned copper |
Insulation | PVC |
Outer sheath | superpolyamide |
Electrical characteristics | |
Maximum operating voltage | 600V |
Mechanical characteristics | |
Cable flexibility | Flexible |
Usage characteristics | |
Electro magnetic interference resistance | Yes |
Operating temperature, range | -40 .. 105°C |
RoHS compliant | Yes |