Description
Standards
International : IEC 60754-1; IEC 60754-2Description
Preferential use
- cable for ETCS balise railway networks
- Siemens CH + DE Approved
Key-points
- for connecting ETCS balise
- SBB I-AT-FS approved - 3001.52.2000
- Siemens approved - MKA 815.1
- Low reduction factor
- Rodent protection
- radial water protection (moisture barrier)
Cable construction
- Conductor: Bare Copper wire
- Insulation: polyethylene
- Stranding
- Screen: Aluminium/polyethylene coated tape longitudinally applied and overlapped
- Intermediate sheath: polyethylene
- Armour: Two galvanized steel tapes
- Outer sheath: Black polyethylene
Remarks:
On request with HFFR sheath
Characteristics
Construction characteristics | |
---|---|
Sheath colour | Black |
Screen | Aluminium coated tape |
Conductor material | Bare copper |
Inner sheath | Polyethylene |
Outer sheath | PE |
Armour type | Galvanized steel tapes |
Halogen free | Yes |
Dimensional characteristics | |
Precision of diameter | +/- 0.7 mm |
Electrical characteristics | |
Dielectric strength core to core DC, min. | 2.5kV |
Dielectric strength core to screen DC, min. | 2.5kV |
Usage characteristics | |
Weather resistance | Good |
Water proof | Radial |
Minimum operating temperature | -30°C |
Maximum operating temperature | 70°C |
Minimum installation temperature | -5°C |
Specific characteristics | |
See all products | |
|
Products and services
Docs and info
CABLE BALISE Transmission Characteristics
Parameter |
Frequency |
Unit |
Value |
Mutual capacity |
800 Hz |
nF/km |
42.3 +/- 15% |
Coppling K1 |
800 Hz |
pF/km |
max. 240 |
Coppling to earth ea1, ea2 |
800 Hz |
pF/km |
max. 640 |
Impedance |
0.56 MHz |
Ohm |
120 +/- 10% |
|
0.80 MHz |
Ohm |
120 +/- 10% |
|
1.8 MHz |
Ohm |
120 +/- 5% |
Attenuation |
8.82 kHz |
dB/100m |
0.08 |
|
0.56 MHz |
dB/100m |
0.40 |
|
0.80 MHz |
dB/100m |
0.50 |
|
1.8 MHz |
dB/100m |
0.80 |
Selling information
Declaration of Performance
Declaration of Performance No: 1000484-CHCD
- Certification Date: 28/06/2017
- AVCP (Assessment and Verification of Constancy of Performance): System 4
- Declared performance: Reaction to fire Fca according to EN50575:2014+A1:2016
Nexans ref. | Country ref. | Product Name |
10178681 | RW-BA-SIEMENS PE-ALT-CLT 1X4/1,53 SW | |
10205675 | RW-BA-SIEMENS PE-ALT-CLT 1X2/1,60 SW |