G7622 A2 Type 2 LUL Railway signalling cables New
Description
Telephone and communications cable for underground / tunnel locations in subway networks.
Description
Telephone and communications cable for underground / tunnel locations in subway networks.
Standards
International : EN 50268-2; IEC 60332-3-24; IEC 60754-1; IEC 60754-2; IEC 61034National : LUL 1-085A3
Description
Multi-pair telephone and communications cable. LS0H Indoor railways cables.
Application
- Telephone and communications cable for underground / tunnel locations in subway networks.
Construction
- Conductor: solid annealed copper 0.63 or 0.90mm
- Insulation: Foam-skin polyethylen
- Quads: Four insulated conductors are twisted and whipped with a binder
- Stranding: Quads are stranded
- Wrapping: PP tape
- Moisture barrier: aluminium/polyethylene laminate, bonded of the sheath
- Sheath: violet coloured LSZH compound
Fire performance
- Flame retardant LUL E 4156 A4 Part 2 10.3
- Low smoke: LUL E 4156 A4 Part 2 10.4
- Halogen free: LUL E 4156 A4 Part 2 10.5
- Non corrosive / toxic gases: LUL E 4156 A4 Part 2 10.5
Standards
- LUL G7622 A2 Type 2
Notes
- Marking: NEXANS-CH G7622 Type 2 - LSC (number of pairs) PR/(size of conductor)MM (meter marking)
Characteristics
Electrical characteristics | |
---|---|
Operating voltage | 50V |
Specific characteristics | |
See all products | |
|
Products and services
Docs and info
-
Color code quads LUL
Position of
quadsCenter and even layers Odd layers A B C D Binder A B C D Binder 1st (marker) Orange white Blue Grey Wh&Or Orange Black Blue Grey
Blk&Or Even quads Red white Violet Yellow White Red Black Violet Yellow Black Odd quads Brown white Green Grey White Brown Black Green Grey Black Last (reference) Orange white Red Green Wh&Or Orange Black Red Green Blk&Or