Description
Standards
International : EN 45545 - HL3; EN 50264-3-1; IEC 60228National : BS 6853 cat 1A; DIN 5510-2, flame protection class 1-4; GOST-R 31565; NFF 16101-cat A1-C/F1; NFPA 130; UNI CEI 11170-3
Description
Application
Installation inside and outside of rolling stock and in cable ducts and tubes. Jumper cable application. In low voltage switch boards the cable can be used as inherently short-circuit and earth-fault proof connection acc. to EN 60364-5-52.
Current carrying capacity acc. to EN 50343 as well as VDE 0298 part 4.
Complies with performance requirements acc. to EN 45545-2 - HL3.
Design
1. Conductor
Flexible stranded tinned copper, class 5 acc. to IEC 60228
Optional halogen-free separator tape
2. Insulation
Cross-linked compound type EI 109 acc. to 50264-1
Colour: grey
3. Sheath
Cross-linked compound type EM 104 acc. to 50264-1
Oil, diesel, ozone and UV resistant
Colour: black
Cable marking
Printing white:
FLAMEX EN 50264-3-1 1800V (mm²) MM NSHXAFOE 1.8/3 kV I NEXANS I WW-YYYY
Characteristics
Construction characteristics | |
---|---|
Halogen free | EN 50267-2-1 & EN 60684-2 |
Sheath colour | Black |
Usage characteristics | |
Operating temperature, range | -40 .. 90°C |
Smoke density | IEC 61034-2 & NFF 16101 |
Gases corrosivity | EN 50267-2-2 |
Gases toxicity | EN 50305-9.2 |
Flame retardant | EN 60332-1-2 |
Fire retardant | EN 60332-3-24 & EN 60332-3-25 |
Bending factor when laying | 10(xD) |
Oil resistance | Yes |
Ozone resistance | Yes |
U.V resistance | Yes |
Specific characteristics | |
See all products | |
|
Products and services
Docs and info
Electrical Properties
Nominal voltage |
Uo/U (Umax) = 1.8/3 (3.6) kV |
Max. operating voltage in DC installations, one-sided earthed |
Vo= 2.7 kV DC |
Testing AC voltage (5 minutes) |
U = 6.5 kV |
Max. operating temperature at conductor
Conductor at normal operation |
≤ 90 °C/250.000 h |
|
≤ 120 °C/20.000 h |
Conductor under short-circuit conditions (tinned) |
≤ 200 °C |