UWM PVC 380 & 600V old
Description
Winding wires for submersible motors, type UWM insulated with special PVC.
Description
Standards
National : DIN 53483; DIN VDE 0472 part 502Description
Winding wires for submersible motors
Driving units of submersible pumps, so called "wet type motors", have been used to a large extent for many years. Due to their simple construction, these motors can be manufactured in comparably small series. This enables end-user countries to set up their own production. This is not possible for canned, oil-filled, motors.
Application
Unlike an oil filled motor, whose insulation would fail due to contact with moisture entering from without, the water filled unit will continue to operate. There is also no danger of polluting water with oil. The advantages of wet type motors; in comparison to canned motors are known all over the world and production of such motors is increasing steadily. The application of this technology though, does not rest solely in the traditional field of submersible pumps. Nowadays, „wet type motors“ are used more and more as driving units of special pumps, dredge boats, submarines, deep-sea research instruments etc.
The winding wires of „wet type motors“ are continually in contact with liquids that are more or less aggressive. For this reason the extruded insulation of the winding wires has to be absolutely water tight and resistant to a number of different substances. The dielectric properties of the insulation (dielectric strength, insulation resistance, dielectric losses), have to meet high standards that, of course, have to be fulfilled under the influence of moisture for long periods of time.
Construction
Due to our longstanding experience and tests, NEXANS has developed its own suitable PVC compound for this special application. Our insulating materials have excellent properties to assure longlivety. Here are some of the main characteristics:
- High dielectric strength
- High insulation resistance
- Low dielectric losses (tan δ)
- Good thermal and chemical resistance
It goes without saying that our laboratory continues to test proven as well as new insulation materials in respect to the suitability for this very specific application. This will assure consistant quality and further improvement.
NEXANS has been in the market of selling water-tight winding wires for submersible pump motors since 1950. NEXANS has, due to longstanding experience, the know-how to develop and use the proper materials. We guarantee the highest standards.
Characteristics
Construction characteristics | |
---|---|
Conductor material | Copper |
Insulation | PVC |
Electrical characteristics | |
Dielectric loss factor (tand maxi =) | 60E-03 |
Breakdown voltage | 55kV |
Test voltage | 5000V |
Mechanical characteristics | |
Tensile strength | 20N/mm2 |
Docs and info
-
Additional Characteristics UWM PVC 380 & 600V
Tests
The following tests are carried out on 100 % of every production lot:
1. Mechanical tests:
a) Dimension of the bare copper conductor
b) Dimension of the insulated wire
c) Eccentricity
d) Surface2. Test voltage and duration of test:
Electrical characteristics
Working voltage 50 Hz 380 V 600 V Test voltage after
24 h in water at 20°C
15 min. 5000 V DC* 5000 V DC* Operating temperature 70°C 70°C Loss factor (acc. to DIN
53483)
20°C/800 Hz
70°C/800 Hz
8 x 10-2
6 x 10-28 x 10-2
6 x 10-2Relative dielectric constant (acc. to DIN
53483)
20°C/800 Hz
70°C/800 Hz
4
84
8Volume resistivity (acc. to VDE 0472,
Teil 502)
20°C/500 V DC
70°C/500 V DC1015 Ω x cm
3 x 1012 Ω x⋅cm31015 Ω x cm
3 x 1012 Ω x⋅cm3Breakdown voltage
measured on wire
1.6/2.4 mm-Ø 20°C
70°C≥ 55 kV/mm
≥ 30 kV/mm≥ 55 kV/mm
≥ 30 kV/mm* Test voltage 2'000 V DC for wire with wall thickness under 0.4mm
Mechanical characteristics
Tensile strength on delivery σ B ≥ 20 N/mm2 Tensile strength after ageing 28 d/80°C ∆ σ B ≤ ± 10 % Elongation at break on delivery ε B ≥ 150 % Elongation at break after ageing (VDE 0472/602) 28 d/80°C ∆ ε B ≤ ± 25 % Hot deformation (reduction of wall thickness) (VDE 0472/609) 80°C/4 h
70°C/4 h≤ 40 %
≤ 25 %Marking
Each bears the following label:
K5
K390/93 & K460/105
Test label
-
Tolerances / Eccentricity UWM
Tolerances
Outer diameter of the insulated wire < 2,20 mm 2,21 – 3,00 mm 3,01 – 4,30mm 4,31 – 6,00 mm Tolerances on outer diameter of the insulated wire ± 0,05 mm ± 0,07 mm ± 0,10 mm ± 0,15 mm Eccentricity ≤ 10 % ≤ 12 % ≤ 15 % ≤ 15 % Definition Eccentricity
-
Electrical specifications UWM
-
Packing UWM
The UWM wire can be packed on 3 kinds of plastic reels.
K5