WINDLINK® LV-UL WTTC shielded

Description
Control cables
UL Type WTTC & TC
UL Subject 2277 & UL Standard 1277

Description
Control cables
UL Type WTTC & TC
UL Subject 2277 & UL Standard 1277Description
Application
Nexans Wind Turbine Tray Cable WINDLINK® LV-UL WTTC was specifically designed to withstand extreme conditions encountered in wind turbine applications.
Product characteristics
- Flame-retardant acc. to CSA FT4 (Vertical Tray)
- Oil-resistant acc. to UL OIL RES I
- UV resistant
- Suitable for torsional applications in wind turbines
- Low transfer impedance
Approvals
- UL MTW
- UL TC-ER 90°C 600V
- UL WTTC 90°C 1000V
- UL DP-1
- UL AWM 600V
- C(UL) CIC/TC
Design
Conductor
Soft annealed copper stranded according to ASTM B 3-95, UL 1581, UL 83 and IEC 60228 cl. 5
Insulation/Nylon jacket
PVC/Nylon acc. to UL 62, UL 83 and UL 1063
Insulation thickness acc. to UL 62 table 6.2, UL 83 Table 10 and
UL 1063 table 1.1
Nylon jacket thickness acc. to UL 62 table 6.2, UL 83 Table 13 and
UL 1063 Table 1.1
16 and 18 AWG: Type TFFN 90°C dry
≤14 AWG: Type THHN 90°C dry / 75°C wet (THWN rating)
Core indification: black numbered + Yellow/Green conductor (where required)
Assembly
Conductors + fillers (where needed for round construction) twisted in layers + polyester tape + Aluminium/Polyester tape (Alu outside)
Shield
Tinned copper braid
Sheath
Special PVC compound acc. to UL 1277 and UL 1063
Thickness acc. to UL 1277 Table 12.3 and UL 1063 Table 13.1
Colour code: Black Ral 9005
Characteristics
Electrical characteristics | |
---|---|
Test voltage | 2500V |
Insulation resistance at 20°C | 20.0MOhm.km |
Max. transfer impedance at 10MHz | 25mOhm/m |
Usage characteristics | |
Ambient dynamic operating temperature, range | -30 .. 90°C |
Ambient static operating temperature, range | -40 .. 90°C |
Minimum bending radius, occasionally moving | 20(xD) |
Minimum bending radius, fixed installation | 5(xD) |
Specific characteristics | |
See all products | |
|
Products and services
Docs and info
Max. conductors resistance at 20°C
Size mm² |
Ω/km |
1.0 |
19.5 |
1.5 |
13.3 |
2.5 |
7.98 |
4.0 |
4.95 |
6.0 |
3.30 |
10 |
1.91 |
16 |
1.21 |
-
Working voltage
- UL AWM 600V
- UL TC-ER / MTW 600V
- UL WTTC 1000V
Selling information
E219385 - CE - Week/Year of production - TYPE WTTC / THHN or THWN 90°C 1000V or MTW 90°C 600 V - n x/G yy mm²/AWG size
n: number of conductors
x/G: without/with Yellow/Green conductor
yy: section of conductor
Meter marking