WINDLINK® LV-RS (N)HXCMFOE
0.6/1 kV

Description
Torsion resistant low-voltage loop cable for free hanging of max. 100 m
Screeened cables acc. to EN 50525-2-21 and EN 50125-3-21
Description
Screeened cables acc. to EN 50525-2-21 and EN 50125-3-21
Standards
International : EN 50525-2-21; EN 50264; EN 50363; IEC 60502Description
Application
Low-voltage loop cable WINDLINK® LV-RS (N)HXCMFOE in two sheath design was developed for special application condition in windturbines. The construction is torsion resistant by free hanging max. 100 m. These cables are specified for medium mechanical stress and for operation under permanent influence of seawater and usage outdoor.
Resistance to:
- Permanent movement
- Permanent vibrations
- Compressive stress
- Oil
- Leach
- Flame-retardant
- Permanent influence of seawater
- Weather
- UV
- Ozone influence, suitable for moving outdoor
- Suitable for torsion up to +/- 80°/meter, test 2,000 cycles
Design
1. Conductor
Copper, plain, flexible stranded, class 5 acc. to DIN EN 60228
2. Insulation
Special EPR thermosetting compound
3. Screen
Tinned wire copper braid, covering min.80%
4. Outer Sheath
Special EVA thermosetting compound, ozone- and UV-resistant, oil-resistant,
colour: black
Operating condition
Temperatures | moved transport and stock operating temperature at conductor short circuit teperature at conductor |
-40+ 90 °C -40/+90 °C 90 °C 250°C |
Max. tensile load | short time, e.g.speed up N/mm² in operation |
50 15 |
Bending radii | fixed free moving Inlet ant strain relief |
³ 3 x D ³ 5 x D ³ 5 x D (D = cable diameter) |
Torsion | max. permissible angle | ± 80 °/m |
Characteristics
Construction characteristics | |
---|---|
Conductor material | Plain annealed copper |
Conductor flexibility | Flexible class 5 |
Insulation | Halogen free compound |
Screen | Tinned copper |
Outer sheath | Special cross-linked elastomer |
Halogen free | IEC 60754-2 |
Sheath colour | Black |
Dimensional characteristics | |
Number of cores | 1 |
Electrical characteristics | |
Rated Voltage Uo/U (Um) | 0.6/ 1 (1.2) kV |
Usage characteristics | |
Flame retardant | EN 60332-1-2 |
RoHS compliant | Yes |
Silicone free | Yes |
Bending factor when installed | 3(xD) |
Bending factor when laying | 5(xD) |
Specific characteristics | |
See all products | |
|