GTM3.1 - Heat-shrinkable three-core transition joint up to 42 kV

Description
GTM3.1 - Heat-shrinkable three-core transition joint up to 42 kV
Description
Standards
International : CENELEC HD 629.2Description
Application
For jointing three-core paper cables to three single core polymeric cables. For use with belted or screened cables with a common or individual lead sheath. This transition joint is fully screened, submersible and suitable to be directly buried.
Specifications and standards
Meets the requirements of CENELEC HD 629.2.
Docs and info
-
Design
1. Dual wall tube
2. Stress control tube
3. Protection tube
4. Hi-K mastic
5. Sealing mastic
6. Screen continuity (copper braid and mesh)
7. Conductor connector (supplied on request)
8. Semi-conductive breakout (17GTM3.1)
9. Semi-conductive tubes (17GTM3.1)
10. Barrier tube
11. Break-out -
Technical data
-
Kit contents
The complete GTM3.1 joint kit comprises the following components:
The kit also comprises:
+ installation instructions
+ mechanical conductor connector
+ mechanical screen wire cable lug
+ roll springs
+ assembly incidentals -
Ordering instructions
Please indicate the part number when ordering (see table).
Select the order designation of the straight joint according to the cable type used and the diameter over core insulation.
Order example:
For a paper-insulated belted cable with 6/10 kV, 3 x 150 mm² on an XLPE-insulated single-core cable with 6/10 kV, 120 mm². Order according to the table: 17GTM3.1.240 part number 59854. -
Pictograms
-
Technical instructions and application information (accessories)
The data given were determined diligently, but do not release our customers of the duty to carry out tests themselves in order to check the suitability of the products delivered by us for the intended use. We reserve the right to modify characteristic and performance data according to the present state of technology. Processing and use of the products cannot be controlled by us and are therefore exclusively in your field of responsibility.
Our products meet the VDE standards respectively correspond to DIN pages and IEC recommendations.
Attention: Before first design in please contact manufacturer.
The products, described in this catalogue, are designed for connection of bare energy cable conductors (Class 1 & 2) with description of round solid (RE), round stranded (RM), as well as sector solid (SE), sector stranded (SM) and round stranded compacted (RMV) for conductor temperatures up to 90 °C. All conductor filling materials like tapes, yarn, powder or similar need to be completely removed before the installation. A check on basis of the actual existing conductor dimensions by the user is indispensable. This applies also for the application of Class 6 conductors or other special conductor types.
Impact wrenches have to be approved by Nexans! Depending on different conductor material or conductor type, indicated values may differ from test values acc. to IEC 61238-1. The use of fine stranded conductors has to be approved by Nexans Power Accessories Germany GmbH.
Our responsibilities are only those listed in the latest edition of “General terms and conditions for the supply of products and services of the electrical and electronics industry”. We can provide a copy on request.
Our products are mainly delivered in cartons. We only use package materials able to be recycled due to the latest packing system. Collapsible cardboard boxes are not taken back. Please try to order complete standard packages.
Reprinting, even partial, only with special allowance. We reserve the right to alter or modify the characteristics described. Illustrations and drawings may only show a close reflection and are not decisive. The weights are approximate and include the carton package. This catalogue substitutes all former editions. Types or versions not part of the catalogue are available on request.
Hof, January 2020