SERVO CABLES ACC. TO BOSCH REXROTH STANDARD

Description
Servo cables according to BOSCH REXROTH standard for extremely dynamic applications, PUR jacket, shielded, resistant to oils, flame retardant, halogen-free
Description
Standards
International : UL and CSA approvalDescription
Normative reference
UL Recognized / CSA
AWM 80°C - 600V/1000V
AWM 80°C - 600V/1000V FT1
Oil Resistance:
En 50363-10-2
Flame Resistance:
IEc 60331-1-2; FT1; UL 1581; EN 50265-2-1
Toxicity:
Halogen free
Characteristics
Construction characteristics | |
---|---|
Conductor material | Stranded bare copper |
Insulation | Polyolefin |
Insulation colour | Power: U/L1/C/L+ V/L2 W/L3/D/L- Ye/Gr Signal: Black num 5-6 7-8 |
Lay Up | power cores and control pairs stranded with filler |
Taping | Non woven tape |
Shielding | ≥85% tinned copper braid coverage |
Outer sheath | PUR |
Sheath colour | Orange RAL 2003 |
Halogen free | Yes |
Electrical characteristics | |
Rated Voltage Uo/U | 0.6/1 kV |
Test voltage | 4000V |
Mechanical characteristics | |
Maximum acceleration | 50m/s² |
Bending cycles | 10.0Mio. |
Speed | 300 m/min |
Usage characteristics | |
Field of application | Dynamic |
Minimum dynamic operating bending radius | 7.5(xD) |
Operating temperature, range | -30 .. 80°C |
Storage temperature, range | -50 .. 80°C |
Oil resistance | EN 50363-10-2 |
Flame retardant | IEC 60332-1-2; FT1; UL 1581; EN 50265-2-1 |
Specific characteristics | |
See all products | |
|