Description
- XLPE insulation (Part 1)
- Armoured (Type 2)
- Individual & Overall Screen (IOS)
- Hydrocarbons resistant
Standards
International : IEC 60332-3-22 Cat.A; IEC 60584-3Description
Applications
These compensation and extension cables are used with thermocouples for temperature measurements . They are well adapted to underground use in industrial applications where hydrocarbons may be present and where chemical and mechanical protections are needed (refinery areas, chemical plant…). The individual screening of each pair limits the consequence of crosstalk.
Design
Conductor:
Metal in accordance with the thermocouple, either solid cross section 0.5 mm² (1 x 0.8 mm), 1.34 mm² (1 x 1.30 mm) or flexible cross-section 1 mm² (14 x 0.30 mm)
Insulation:
Cross-linked polyethylene (XLPE)
Individual screen:
Binder tape
Tinned copper drain wire
Aluminium backed polyester tape
Binder tape
Overall screen:
Binder tape
Tinned copper drain wire
Aluminium backed polyester tape
Bedding (inner sheath) :
Polyvinyl chloride (PVC)
Colour : depends on thermocouple type
Armour:
Galvanized steel wires (SWA)
Outer sheath:
Polyvinyl chloride (PVC)
Colour: depends on thermocouple type
Core identification
See "identification sheet"
Marking
NEXANS 279 XLPE/IND+OA.SCR/PVC/SWA/PVC 300/500 V Nber of pairs & cross section Type of thermocouple IEC 60332-3-22(A) MM YYYY Manufacturing number + meter marking.
Standards
PAS 5308 Part1/Type 2
BS EN 50290-2-29
Characteristics
Construction characteristics | |
---|---|
Insulation | XLPE (Cross-linked Polyethylene) |
Individual screen | Tinned copper drain wire + aluminium/polyester tape |
Overall screen | Tinned copper drain wire + aluminium/polyester tape |
Inner sheath | PVC |
Armour type | Galvanized steel wires |
Outer sheath | PVC |
Protection | Yes |
Dimensional characteristics | |
Conductor cross-section | 1.34mm² |
Number of pairs | 30 |
Conductor diameter | 1.3mm |
Diameter over insulation | 2.56mm |
Diameter over armour | 39.6mm |
Minimum outer diameter | 43.1mm |
Maximum outer diameter | 47.5mm |
Approximate weight | 3321kg/km |
Diameter over inner sheath | 35.6mm |
Electrical characteristics | |
Rated Voltage Uo/U (Um) | 300 / 500 V |
Mechanical characteristics | |
Mechanical resistance to impacts | Good |
Usage characteristics | |
Fire retardant | IEC 60332-3-22 |
Chemical resistance | Hydrocarbons resistant |
Electro magnetic interference resistance | Yes |
Operating temperature, range | -20 .. 60°C |
Max. conductor temperature in service | 90°C |
Standard | PAS |
Docs and info
* Thermocouple type
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TC – Copper/copper nickel for copper/copper nickel thermocouple |
|
|
|
|
|
|
|
JC – Iron/copper nickel for iron/copper nickel thermocouple |
|
|
|
|
|
|
|
EC – Nickel chromium/copper nickel for nickel chromium/copper nickel thermocouple |
|
|
|
|
|
|
|
KC – Nickel chromium/nickel aluminium for nickel chromium/nickel aluminium thermocouple |
|
|
|
|
|
|
|
KCA – Iron/copper nickel for nickel chromium/nickel aluminium thermocouple |
|
|
|
|
|
|
|
KCB – Copper/copper nickel for nickel chromium/nickel aluminium thermocouple |
|
|
|
|
|
|
|
NC – Nickel chromium silicium/nickel silicium for nickel chromium silicium/nickel silicium thermocouple |
|
|
|
|
|
|
|
SC RC – Copper/copper nickel for platinium rhodium thermocouple |
|
|
|
|
|
|
|
BC – Copper/copper alloy for platinium rhodium/platinium rhodium thermocouple |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Selling information
Other fire performances IEC 60332-1 or IEC 60332-3-24(C) and enhanced hydrocarbon resistance on request.
Minimum bending radius:
10 x outer diameter
To be doubled during laying operations