Description
- Overall Screen (OS)
- Hydrocarbons resistant
Standards
International : IEC 60332-3-22 Cat.A; IEC 60584-3National : NF C 42-324
Description
Applications
These compensation and extension cables are used with thermocouples for temperature measurements. They are well adapted to underground use in industrial applications where hydrocarbons may be present and mechanical protections are needed (refinery areas, chemical plant…).
Design
Conductor:
Metal in accordance with the thermocouple, either solid of cross-section 0.5 mm² (1 x 0.8 mm), 1.34 mm² (1 x 1.30 mm) or stranded cross-section 1 mm² (14 x 0.30 mm)
Insulation:
Polyvinyl chloride (PVC)
Overall screen:
Polyester tape
Tinned copper drain wire
Aluminium/polyester tape
Inner Sheath:
Polyvinyl chloryde (PVC)
Armour :
Paraffin-waxed crepe paper
Double steel tape
Outer sheath:
Polyvinyl chloride (PVC)
Colour: depends on thermocouple type
Core identification
See "identification sheet"
Standards
NF M 87201
Marking
For type JC - TC - EC - KC - BC: Type - (Class) - Nbre of pair and cross-section - GORSE - IEC 60332-3-22(A) + metric marking
For type KCA - KCB - NC - SCA - SCB - RCA - RCB (IEC 60584-3) IEC - type - (Class) - Nbre of pair and cross-section - GORSE - IEC 60332-3-22(A) + metric marking
Characteristics
Construction characteristics | |
---|---|
Insulation | PVC |
Overall screen | Tinned copper drain wire + aluminium/polyester tape |
Inner sheath | PVC |
Armour type | Two steel tapes |
Outer sheath | PVC |
Protection | Yes |
Dimensional characteristics | |
Conductor cross-section | 0.5mm² |
Number of pairs | 12 |
Conductor diameter | 0.8mm |
Diameter over insulation | 1.6mm |
Diameter over inner sheath | 14mm |
Diameter over armour | 15.6mm |
Minimum outer diameter | 17.3mm |
Maximum outer diameter | 19.8mm |
Approximate weight | 470kg/km |
Electrical characteristics | |
Operating voltage | 250V |
Mechanical characteristics | |
Mechanical resistance to impacts | Good |
Usage characteristics | |
Fire retardant | IEC 60332-3-22 |
Chemical resistance | Hydrocarbons resistant |
Electro magnetic interference resistance | Yes |
Operating temperature, range | -20 .. 60°C |
Max. conductor temperature in service | 70°C |
Standard | NFM |
Docs and info
* Thermocouple type
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TC – Copper/copper nickel for copper/copper nickel thermocouple |
|
|
|
|
|
|
|
JC – Iron/copper nickel for iron/copper nickel thermocouple |
|
|
|
|
|
|
|
EC – Nickel chromium/copper nickel for nickel chromium/copper nickel thermocouple |
|
|
|
|
|
|
|
KC – Nickel chromium/nickel aluminium for nickel chromium/nickel aluminium thermocouple |
|
|
|
|
|
|
|
KCA – Iron/copper nickel for nickel chromium/nickel aluminium thermocouple |
|
|
|
|
|
|
|
KCB – Copper/copper nickel for nickel chromium/nickel aluminium thermocouple |
|
|
|
|
|
|
|
NC – Nickel chromium silicium/nickel silicium for nickel chromium silicium/nickel silicium thermocouple |
|
|
|
|
|
|
|
SC RC – Copper/copper nickel for platinium rhodium thermocouple |
|
|
|
|
|
|
|
BC – Copper/copper alloy for platinium rhodium/platinium rhodium thermocouple |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Selling information
Minimum bending radius:
10 x outer diameter
To be doubled during laying operations