LANmark-OF UC Universal 24x Singlemode 9/125 OS2 LSZH Eca Black


Eca

See all LANmark-OF UCUN (Unitube Steel Armoring - Universal) Eca products
Description
- Indoor/Outdoor cable
- Corrugated steel tape armour
- Gel filled tube
- All fibre grades
- Provides full rodent protection
- Low Smoke Zero Halogene (LSZH)
Standards
International : ISO/IEC 11801Declaration of Performance : Reaction to fire: Eca
according to EN50575:2014+A1:2016
Description
Description and Application
The construction is suitable for indoor/outdoor use. It consists of a corrugated steel tape armouring providing full rodent protection. It is surrounded by glass yarns. The cable has a LSZH outer jacket.
The loose tube design has a capacity of up to 24 fibres. Diameter of the fibres is 250 um. Termination of these fibres is done with splicing of pigtails.
The cable is watertight due to the gel in the loose tube and the watertight glass yarns.
Construction
Legend accompanying the cross section drawing:
- Optical fibres (250 um)
- Gel
- Loose tube
- Reinforced watertight glass yarns
- Corrugated steel tape armour
- LSZH outer jacket with UV resistant additive
Characteristics
- Indoor/Outdoor cable
- Flame retardant (IEC 60332-1 and NFC 32070 C2) and fire retardant (IEC 60332-3 and NFC 32070 C1)
- Designed for termination by splicing
- Central loose tube design
- Corrugated steel protection
- Waterproof structure, rodent resistant and UV-resistant
- Available in all fibre grades
- Available from 4-24 fibres
Characteristics
Construction characteristics | |
---|---|
Fiber optic type | SM (G657.A1) |
Dimensional characteristics | |
Number of optical fibres | 24 |
Nominal outer diameter | 8.5mm |
Approximate weight | 104kg/km |
Mechanical characteristics | |
Maximum pulling force (IEC 60794-1-2-E1) | 1500N |
Maximum operating pulling force | 450N |
Mechanical resistance to impacts | 3 impacts of 5 N.m |
Crush resistance (IEC 60794-1-E3) | 300N/cm |
Usage characteristics | |
Flame retardant | IEC 60332-1 |
Fire retardant | IEC 60332-3 |
Minimum static operating bending radius | 130mm |
Minimum dynamic operating bending radius | 170.0mm |
Ambient installation temperature, range | 0 .. 40°C |
Operating temperature, range | -40 .. 60°C |
Storage temperature, range | -40 .. 60°C |