WINDLINK® LV-UL WTTC shielded

Products

LV UL WTTC (12G1.5)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 12 G 1.5
  • Number of cores: 12
  • Conductor cross-section: 1.5 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 14.8 mm
  • Approximate weight: 387 kg/km
  • Copper content: 240 kg/km
  • Nominal resistance of the conductor: 13.30 Ohm/km

 

LV UL WTTC (18G1)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 18 G 1.0
  • Number of cores: 18
  • Conductor cross-section: 1 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 15.4 mm
  • Approximate weight: 414 kg/km
  • Copper content: 227 kg/km
  • Nominal resistance of the conductor: 19.50 Ohm/km

 

LV UL WTTC (18G1.5)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 18 G 1.5
  • Number of cores: 18
  • Conductor cross-section: 1.5 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 17.2 mm
  • Approximate weight: 548 kg/km
  • Copper content: 321 kg/km
  • Nominal resistance of the conductor: 13.30 Ohm/km

 

LV UL WTTC (19G1)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 19 G 1.0
  • Number of cores: 19
  • Conductor cross-section: 1 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 15.6 mm
  • Approximate weight: 438 kg/km
  • Copper content: 236 kg/km
  • Nominal resistance of the conductor: 19.50 Ohm/km

 

LV UL WTTC (2x6)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 2 x 6
  • Number of cores: 2
  • Conductor cross-section: 6 mm²
  • Insulation sheath thickness: 0.51 mm
  • Nominal outer diameter: 12.7 mm
  • Approximate weight: 187 kg/km
  • Copper content: 164 kg/km
  • Nominal resistance of the conductor: 3.30 Ohm/km

 

LV UL WTTC (25G1.5)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 25 G 1.5
  • Number of cores: 25
  • Conductor cross-section: 1.5 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 20.2 mm
  • Approximate weight: 731 kg/km
  • Copper content: 472 kg/km
  • Nominal resistance of the conductor: 13.30 Ohm/km

 

LV UL WTTC (25G1)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 25G1
  • Number of cores: 25
  • Conductor cross-section: 1 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 18.1 mm
  • Approximate weight: 923 kg/km
  • Copper content: 560 kg/km
  • Nominal resistance of the conductor: 19.50 Ohm/km

 

LV UL WTTC (3G1)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 3 G 1.0
  • Number of cores: 3
  • Conductor cross-section: 1 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 8.1 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 19.50 Ohm/km

 

LV UL WTTC (3G1.5)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 3 G 1.5
  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 8.6 mm
  • Approximate weight: 124 kg/km
  • Copper content: 68 kg/km
  • Nominal resistance of the conductor: 13.30 Ohm/km

 

LV UL WTTC (3G10)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 3 G 10
  • Number of cores: 3
  • Conductor cross-section: 10 mm²
  • Insulation sheath thickness: 0.76 mm
  • Nominal outer diameter: 18.2 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 1.91 Ohm/km

 

LV UL WTTC (3G16)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 3 G 16
  • Number of cores: 3
  • Conductor cross-section: 16 mm²
  • Insulation sheath thickness: 0.76 mm
  • Nominal outer diameter: 21.2 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 1.21 Ohm/km

 

LV UL WTTC (3G2.5)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 3 G 2.5
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 9.6 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 7.98 Ohm/km

 

LV UL WTTC (3G4)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 3 G 4
  • Number of cores: 3
  • Conductor cross-section: 4 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 11.0 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 4.95 Ohm/km

 

LV UL WTTC (3G6)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 3 G 6
  • Number of cores: 3
  • Conductor cross-section: 6 mm²
  • Insulation sheath thickness: 0.51 mm
  • Nominal outer diameter: 13.1 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 3.30 Ohm/km

 

LV UL WTTC (4G1)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 4 G 1.0
  • Number of cores: 4
  • Conductor cross-section: 1 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 8.7 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 19.50 Ohm/km

 

LV UL WTTC (4G1.5)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 4 G 1.5
  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 9.2 mm
  • Approximate weight: 156 kg/km
  • Copper content: 86 kg/km
  • Nominal resistance of the conductor: 13.30 Ohm/km

 

LV UL WTTC (4G10)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 4 G 10
  • Number of cores: 4
  • Conductor cross-section: 10 mm²
  • Insulation sheath thickness: 0.76 mm
  • Nominal outer diameter: 21.2 mm
  • Approximate weight: 822 kg/km
  • Copper content: 517 kg/km
  • Nominal resistance of the conductor: 1.91 Ohm/km

 

LV UL WTTC (4G16)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 4 G 16
  • Number of cores: 4
  • Conductor cross-section: 16 mm²
  • Insulation sheath thickness: 0.76 mm
  • Nominal outer diameter: 23.5 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 1.21 Ohm/km

 

LV UL WTTC (4G2.5)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 4 G 2.5
  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 10.5 mm
  • Approximate weight: 216 kg/km
  • Copper content: 130 kg/km
  • Nominal resistance of the conductor: 7.98 Ohm/km

 

LV UL WTTC (4G4)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 4 G 4
  • Number of cores: 4
  • Conductor cross-section: 4 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 11.6 mm
  • Approximate weight: 280 kg/km
  • Copper content: 205 kg/km
  • Nominal resistance of the conductor: 4.95 Ohm/km

 

LV UL WTTC (4G6)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 4 G 6
  • Number of cores: 4
  • Conductor cross-section: 6 mm²
  • Insulation sheath thickness: 0.51 mm
  • Nominal outer diameter: 14.9 mm
  • Approximate weight: 445 kg/km
  • Copper content: 306 kg/km
  • Nominal resistance of the conductor: 3.30 Ohm/km

 

LV UL WTTC (5G1)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 5 G 1.0
  • Number of cores: 5
  • Conductor cross-section: 1 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 9.3 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 19.50 Ohm/km

 

LV UL WTTC (5G1.5)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 5 G 1.5
  • Number of cores: 5
  • Conductor cross-section: 1.5 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 10.1 mm
  • Approximate weight: 188 kg/km
  • Copper content: 108 kg/km
  • Nominal resistance of the conductor: 13.30 Ohm/km

 

LV UL WTTC (5G10)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 5 G 10
  • Number of cores: 5
  • Conductor cross-section: 10 mm²
  • Insulation sheath thickness: 0.76 mm
  • Nominal outer diameter: 23.3 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 1.91 Ohm/km

 

LV UL WTTC (5G16)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 5 G 16
  • Number of cores: 5
  • Conductor cross-section: 16 mm²
  • Insulation sheath thickness: 0.76 mm
  • Nominal outer diameter: 26.2 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 1.21 Ohm/km

 

LV UL WTTC (5G2.5)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 5 G 2.5
  • Number of cores: 5
  • Conductor cross-section: 2.5 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 11.2 mm
  • Approximate weight: 244 kg/km
  • Copper content: 139 kg/km
  • Nominal resistance of the conductor: 7.98 Ohm/km

 

LV UL WTTC (5G4)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 5 G 4
  • Number of cores: 5
  • Conductor cross-section: 4 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 13.1 mm
  • Approximate weight: 344 kg/km
  • Copper content: 252 kg/km
  • Nominal resistance of the conductor: 4.95 Ohm/km

 

LV UL WTTC (5G6)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 5 G 6
  • Number of cores: 5
  • Conductor cross-section: 6 mm²
  • Insulation sheath thickness: 0.51 mm
  • Nominal outer diameter: 16.4 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 3.30 Ohm/km

 

LV UL WTTC (7G1)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 7 G 1.0
  • Number of cores: 7
  • Conductor cross-section: 1 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 10.1 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 19.50 Ohm/km

 

LV UL WTTC (7G1.5)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 7 G 1.5
  • Number of cores: 7
  • Conductor cross-section: 1.5 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 11.0 mm
  • Approximate weight: 228 kg/km
  • Copper content: 143 kg/km
  • Nominal resistance of the conductor: 13.30 Ohm/km

 

LV UL WTTC (7G10)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 7 G 10
  • Number of cores: 7
  • Conductor cross-section: 10 mm²
  • Insulation sheath thickness: 0.76 mm
  • Nominal outer diameter: 25.5 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 1.91 Ohm/km

 

LV UL WTTC (7G16)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 7 G 16
  • Number of cores: 7
  • Conductor cross-section: 16 mm²
  • Insulation sheath thickness: 0.76 mm
  • Nominal outer diameter: 28.4 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 1.21 Ohm/km

 

LV UL WTTC (7G2.5)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 7 G 2.5
  • Number of cores: 7
  • Conductor cross-section: 2.5 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 12.4 mm
  • Approximate weight: 322 kg/km
  • Copper content: 188 kg/km
  • Nominal resistance of the conductor: 7.98 Ohm/km

 

LV UL WTTC (7G4)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 7 G 4
  • Number of cores: 7
  • Conductor cross-section: 4 mm²
  • Insulation sheath thickness: 0.38 mm
  • Nominal outer diameter: 14.8 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 4.95 Ohm/km

 

LV UL WTTC (7G6)C

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 7 G 6
  • Number of cores: 7
  • Conductor cross-section: 6 mm²
  • Insulation sheath thickness: 0.51 mm
  • Nominal outer diameter: 17.7 mm
  • Approximate weight: - kg/km
  • Copper content: - kg/km
  • Nominal resistance of the conductor: 3.30 Ohm/km

 

Description

Description

Application
Nexans Wind Turbine Tray Cable WINDLINK® LV-UL WTTC was specifically designed to withstand extreme conditions encountered in wind turbine applications. 

Product characteristics

  • Flame-retardant acc. to CSA FT4 (Vertical Tray)
  • Oil-resistant acc. to UL OIL RES I
  • UV resistant
  • Suitable for torsional applications in wind turbines
  • Low transfer impedance

Approvals

  • UL MTW 
  • UL TC-ER 90°C 600V
  • UL WTTC 90°C 1000V
  • UL DP-1
  • UL AWM 600V

Working voltage

  • UL AWM 600V
  • UL TC-ER / MTW 600V
  • UL WTTC 1000V

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft annealed copper
Insulation
PVC compound
Individual sheath
Nylon jacketing compound
Insulation colour
Black numbered Yellow/Green
Screen
Tinned copper braid
Taping
Aluminium / Polyester tape
Outer sheath
Special PVC compound
Sheath colour
Black - RAL 9005

Dimensional characteristics

Dimensional characteristics

Inner sheath thickness
- mm
Maximum cable diameter
- mm
Minimum cable diameter
- mm
Nominal outer sheath thickness
- mm

Electrical characteristics

Electrical characteristics

Test voltage
2500 V
Insulation resistance at 20°C
20 MOhm.km
Inductive reactance
- Ohm/km
Max. Electrical Resistance AC 60Hz 70°C
- Ohm/km
Max. Electrical Resistance AC 60Hz 90°C
- Ohm/km
Nominal Voltage
600 V
Permissible current rating in open air
- A
Permissible short circuit current
- kA

Usage characteristics

Usage characteristics

Ambient dynamic operating temperature, range
-5 ... 90 °C
Ambient static operating temperature, range
-40 ... 90 °C
Oil resistance
Oil resistance I
Minimum bending radius, occasionally moving
8 (xD)
Minimum bending radius, fixed installation
4 (xD)
Flame retardant
UL 1581 SEC. 1160 AND CSA FT4
Gases corrosivity
-
Installation temperature, range
- °C
Max. conductor temperature in service
- °C
Ozone resistance
-
Short-circuit max. conductor temperature
- °C
U.V resistance
-

Resources

Resources

Documentation

xls — 0 B

Selling & delivery Information

Marking

E219385 - CE - Week/Year of production - TYPE WTTC / THHN or THWN 90°C 1000V or MTW 90°C 600 V - n x/G yy mm²/AWG size

n: number of conductors
x/G: without/with Yellow/Green conductor
yy: section of conductor
Meter marking

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close